video
3 Phase Pump Controller for Water Supply From Wells

3 Phase Pump Controller for Water Supply From Wells

Rated Input Voltage:AC380V Three phase 50HZ/ 60HZ
Rated Output Power:0.75KW-15KW (1HP-20HP)
Capacitor:N/M

Chat Now
Product Introduction

3 Phase Pump Controller For Water Supply From Wells

Product Details:


Place of Origin:China


BrandName:LEADING


Certification:CE


Model Number:L932


Payment & Shipping Terms:


Minimum Order Quantity:1 set


Price:Negotiable


PackagingDetails:Carton


Delivery Time:30-35 days


Payment Terms:D/A, L/C, D/A, D/P, T/T


Supply Ability:5000 Pcs / Each Month



Detailed Product Description

Phase:

Three Phase

Pump Controlled Quantity:

Two Pumps

Enclosure Protection Grade:

IP54

Install Position:

Wall Mounting

Displaying :

LCD Display

Liquid Level Transfer Distance:

≤1000m


Products Brief :

L932 is applied for automatic liquid level control / pressure control and effective protection for duplex pumps of with AC220V, 50hz, single phase output power 0.75KW-15KW (1HP-20HP),direct start, including stainless steel or cast iron submersible pump,centrifugal pump, sewage pump etc.

Model L932 has many operation modes by adopting the digital control chip, set upper and down liquid level and automatic control in one function. Automatic and manual two working mode can be selected..the controller have loss phase, overload, empty load, over voltage and under voltage function protection. Small size .elegant appearance. Applicable to a variety of water supply control occasions.


Typical Usage Scenarios Include:
●Houses
●Flats
●Holidays houses
●Farms
●Water supply from wells
●Irrigations of greenhouses, gardens, agriculture
●Rain water reuse
●Industrial plants
●Waste water tank / Sewage sink


Main Technical Specifications

■Rated Input Voltage…………………………………………AC380V / Three Phase

■ Rated Frequency…………………………………………50Hz-60Hz (at option)

■ Rated Output Power of Motor……………0.75-4KW / 5.5-11KW/15KW(at option)

■ Open Phase Trip Response Time…….……………………2sec

■ Short Circuit Trip Response Time……………………………………………0.1sec

■ Dry Running Trip Response Time………………………………………………6sec

■ Over / Under Voltage Trip Response Time……………………………………5sec

■ Pump Stalled Trip Response Time……………………..………0.5sec

■ Over Current Trip Response Time……………………………………5sec-5min ①

■ Recovery Time of Over / Under Voltage……………………………………2min

■ Recovery Time of Over Current…………………………………………30min

■ Recovery Time of Dry Running.………………………………………………30min

■ Over / Under Voltage Trip……..……………………….……………..…….±15%

■ Dry Running Trip……………………………………………….70%

■ Pump Stalled Trip………………………………………….……………………200%


① the Characteristic of Inverse-time, the stronger of the current, The shorter of trip response time)

② Percent of rated input voltage ( i.e if the rated input voltage is 380V, the Over voltage trip is 437V, the Under voltage trip is 323V)

③ Percent of load time of calibration ( i.e if the running ampere of pump motor is 10A during the calibration, the dry running trip ampere is 7A)

④ Percent of load time of calibration ( i.e if the running ampere of pump motor is 10A during the calibration, The pump stalled trip ampere is 20A)


Start type

Direct on line

Qty of controlled pump

Two pumps

Rated input voltage:

AC380V Three phase

50HZ/ 60HZ

Rated output power:

0.75KW-15KW (1HP-20HP)

Capacitor:

N/M



Protection Offered:

Dry run

Over load

Transient surge

Under voltage

Over voltage

Open phase

Pump shaft rust protection

Pump stalled

Short circuit

Over temp

Three phase unbalance

Phase reversal

Repeated start



Application &

Control characteristic

Control and protect universal pump

Using water level sensor or float switch to control pump start and stop

Applied for water supply by liquid level control through float switch or liquid probe

Applied for water supply by pressure control through pressure switch and pressure tank

Applied for drainage by liquid level control through float switch or liquid probe


Other features

Push button calibration

Memory function when power off & recovery

Pump Accumulative Running Time Displaying

Pump Last Five Fault Record Displaying

Interactive LCD Screen

20170907153402_81713

Working temperature

Working humidity

Degree of protection

Install position

Unit dimension (L x W x H)

-25℃-- +55℃

20%--90%RH, no drips concreted

IP54

Wall mounting

30.2 x 24x 12cm


Leading Science & Technology company has been providing pump control and protection solutions to pump users.We have obtained such Certificates as follow:

1.Standard:Certification of Quality Management System

Number:06518Q30586R3M

Issue Date:2018-03-26

Expiry Date:2021-03-25

Scope/Range:design and production of pump,valve,fan control system

Issued By:CFL Certification Center

2.Standard:CE

Number:SHEM180300220001TX

Issue Date:2018-04-19

Issued By:SGS-CSTC Standards Technical Services (Shanghai) CO.,LTD

Tag: duplex pump control panel, duplex sump pump control panel

Hot Tags: 3 phase pump controller for water supply from wells, China, manufacturers, suppliers, factory, price, made in China, Sewage Pump Controller With Three Phase Control Panel, Duplex Pump Controller For Waste Water Tank Sewage Sink, Mobile Automatic Water Pump Controller With Starter, Three Phase Two Pumps Duplex Pump Controller In Doi Start, Three Phase Duplex Pump Controller For Drainage Pump, Sewage Pump Controller For 3 Phase Under Voltage Protection

Send Inquiry

whatsapp

Phone

E-mail

Inquiry

Bag