Duplex Pump Controller Dry Run Protection For Sewage Pumping System
| Product Details: Place of Origin:China BrandName:LEADING Certification:CE Model Number:L932-S Payment & Shipping Terms: Minimum Order Quantity:1 set Price:Negotiable PackagingDetails:Carton Delivery Time:30-35 days Payment Terms:D/A, L/C, D/A, D/P, T/T Supply Ability:5000 Pcs / Each Month |
Detailed Product Description
Phase: | Three Phase | Pump Controlled Quantity: | Two Pumps |
Enclosure Protection Grade: | IP54 | Install Position: | Wall Mounting |
Displaying : | LCD Display |
Model: L932-S
Products Brief :
Model L932/S is specially designed for sewage pumping system, by adopting level transmitter with 0.5-4.5V analog signal, pump user can easily set the different liquid depth for sewage pump operation and observe the dynamic liquid depth in the sump or sewage tank.
Typical Usage Scenarios Include:
●Houses
●Flats
●Holidays houses
●Farms
●Industrial plants
●Construction site
Main Technical Specifications
■Rated Input Voltage………………………………………AC380V / Three Phase
■ Rated Frequency…………………………………………50Hz-60Hz (at option)
■ Rated Output Power of Motor……………0.75-4KW / 5.5-11KW/15KW(at option)
■ Open Phase Trip Response Time…….……………………2sec
■ Short Circuit Trip Response Time……………………………………………0.1sec
■ Dry Running Trip Response Time………………………………………………6sec
■ Over / Under Voltage Trip Response Time……………………………………5sec
■ Pump Stalled Trip Response Time……………………..………0.5sec
■ Over Current Trip Response Time……………………………………5sec-5min
■ Recovery Time of Over / Under Voltage……………………………………2min
■ Recovery Time of Over Current…………………………………………30min
■ Recovery Time of Dry Running.………………………………………………30min
■ Over / Under Voltage Trip……..………………….…………………..…….±15%
■ Dry Running Trip……………………………………………….70%
■ Pump Stalled Trip………………………………………….……………………200%
① the Characteristic of Inverse-time, the stronger of the current, The shorter of trip response time)
② Percent of rated input voltage ( i.e if the rated input voltage is 380V, the Over voltage trip is 437V, the Under voltage trip is 323V)
③ Percent of load time of calibration ( i.e if the running ampere of pump motor is 10A during the calibration, the dry running trip ampere is 7A)
④ Percent of load time of calibration ( i.e if the running ampere of pump motor is 10A during the calibration, The pump stalled trip ampere is 20A)
Application | Control & protect sewage / drainage pump only |
Model | L932-S |
Start type | Direct on line |
Qty of controlled pump | Duplex pump |
Rated input voltage: | AC380V Three phase 50HZ/ 60HZ |
Rated output power: | 0. 75kw-4kw (1 hp-5. 5hp) 15kw (20hp) |
Protection function | Over load protection Pump stalled protection Dry run protection Under voltage protection Repeat start protection Phase unbalance protection Phase reversal protection Open phase protection |
Control characteristic | Connecting 0.5-4.5V level transmitter to replace float switch or level probe Duplex pump control .Main pump / standby pump automatically alternate .Main pump / standby pump automatically switch against malfunction .Standby pump participate running if required |
Other features | LCD screen displaying dynamic real time depth & pump running status
Pump shaft anti-rusty Pump accumulative running time recording Pump last five faults recording displaying Presenting one dry contact point (BA port) Present RS485 port Present user remote monitor LCD screen locked function under Auto state Push button calibration |
Working temperature Working humidity Degree of protection Install position Unit dimension (L x W x H) | -25℃-- +55℃ 20%--90%RH, no drips concreted IP54 Wall mounting 310 x 220x 1 20mm |
Feedback:
Leading Science & Technology company has been providing pump control and protection solutions to pump users.
We WARMLY appreciate your positive feedback. We value our customers so much.If you have any problem, PLEASE FEEL FREE and DON'T HESITATE TO CONTACT US BY EMAIL IMMEDIATEDLY, we are always there to offer help.
Tag: duplex pump control panel, duplex alternating pump controller
Hot Tags: duplex pump controller dry run protection for sewage pumping system, China, manufacturers, suppliers, factory, price, made in China, Three Phase Duplex Pump Controller For Drainage Pump, Duplex 3 Phase Water Pump Controller Build In Switch, Mobile Automatic Water Pump Controller With Starter, IP54 Duplex Pump Controller, L932 Duplex Pump Controller Over Temp Protection For Wastewater, Plants Booster Duplex Pump Controller