380V Three Phase Water Pump Control Box

380V Three Phase Water Pump Control Box

Pump Controlled Quantity:One Pump
Displaying:LCD Display
Unit Dimensions ( L X W X H):30.2 X 24x 12cm

Chat Now
Product Introduction

After experiences and improvements in the long run, our Sewage Pump Controller With Three Phase Control Panel, Intelligent Digital Pump Controller With 3 Phase Pump Control Panel, Dual Pump Control Panel Pressure Control For Centrifugal Water Pump has a broad range of application values. Our company set development, design, production, sales in one with modern production equipment, advanced production technology and business management concept. We believe 'Quality is the life of the company, Delivery is the promise to the custmoers'. And we sincerely hopes to establish win-win business with overseas and domestic customers. We will unswervingly implement the business philosophy of 'customer first' and perfect the enthusiastic after-sales service.

Single Pump Water Pump Controller, Single Phase Submersible Control Panel For Flats


Product Details:


Place of Origin:CHINA


Brand Name:LEADING


Certification:CE


Model Number:L921


Payment & Shipping Terms:


MinimumOrderQuantity:1 set


Price:Negotiable


PackagingDetails:Carton


Delivery Time:30-35 days


Payment Terms:D/A, D/P, T/T



Detailed Product Description

Phase:

Single Phase

Pump Controlled Quantity:

One Pump

Enclosure Protection Grade:

IP54

Displaying:

LCD Display

Liquid Level Transfer Distance:

≤1000m

Unit Dimensions ( L X W X H):

30.2 X 24x 12cm


Products Brief :

L921 is applied for automatic liquid

level control / pressure control and effective protection for duplex pumps of with AC220V, 50hz, single phase output power 0.37 to 4kw (0.5hp-5.5hp),direct start, including stainless steel or cast iron submersible pump,centrifugal pump, sewage pump etc.Model L921 has many operation modes by adopting different electric installations. An important feature that makes the difference between Model L921 and common On/Off pump control box is the probe / sensor free in the well. Our special design makes it a very reliable and sensitive Protection against pump dry run without installation probe / sensor in the well.

Model L921 is useful in all cases we need to control and protect single pump managing its turn-on and turn off by different electric installations.


Typical Usage Scenarios Include:
Houses
Flats
Holidays houses
Farms
Water supply from wells
Irrigations of greenhouses, gardens, agriculture
Rain water reuse
Industrial plants
Waste water tank / Sewage sink


Main Technical Specifications

■ Rated Input Voltage…………………………………………………AC220V / Single Phase

■ Rated Frequency………………………………………………….……50Hz-60Hz (at option)

■ Rated Output Power of Motor………………………………0.37-2.2KW / 3-4KW(at option)

■ Short Circuit Trip Response Time………………………………………………………0.1sec

■ Dry Running Trip Response Time………………………………………………..……6sec

■ Over / Under Voltage Trip Response Time……………………………………….…5sec

■ Pump Stalled Trip Response Time……………………..………………………….0.5sec

■ Over Current Trip Response Time………………………………………………5sec-5min

■ Recovery Time of Over / Under Voltage………………………………………..……2min

■ Recovery Time of Over Current…………………………………………………..…30min

■ Recovery Time of Dry Running.…………………………………………………..……30min

■ Over / Under Voltage Trip……..……………………………….…………………..……±15%

■ Dry Running Trip……………………………………………….…………………..………70%

■ Pump Stalled Trip………………………………………….……………………..……200%


① the Characteristic of Inverse-time, the stronger of the current, The shorter of trip response time)

② Percent of rated input voltage ( i.e if the rated input voltage is 220V, the Over voltage trip is

253V, the Under voltage trip is 187V)

③ Percent of load time of calibration ( i.e if the running ampere of pump motor is 6A during the

calibration, the dry running trip ampere is 4.2A)

④ Percent of load time of calibration ( i.e if the running ampere of pump motor is 6A during the

calibration, The pump stalled trip ampere is 12A)

HTTP: www.leading-china.com

E-mail:stevenma89@hotmail.com


Model

L921

Start type

Direct on line

Qty of controlled pump

Single pump

Rated input voltage:

AC220V-240V Single phase

50HZ/ 60HZ

Rated output power:

0.37kw-2.2kw (0.5hp-3hp)

Capacitor:

Reserved space for installing start capacitor



Protection Offered:

Over load protection

Pump stalled protection

Dry run protection with sensor free

Under voltage protection

Over voltage protection



Application &

Control characteristic

Control and protect universal pump

Using water level sensor or float switch to control pump start and stop

Applied for water supply by liquid level control through float switch or liquid probe

Applied for water supply by pressure control through pressure switch and pressure tank

Applied for drainage by liquid level control through float switch or liquid probe


Other features

Push button calibration

Memory function when power off & recovery

Interactive LCD Screen

20170906162846_26890


Working temperature

Working humidity

Degree of protection

Install position

Unit dimension (L x W x H)

-25℃-- +55℃

20%--90%RH, no drips concreted

IP54

Wall mounting

30.2 x 24x 12cm

Tag: single phase pump controller,single phase submersible pump control panel

We believe we will be able to bring you the most satisfactory 380V Three Phase Water Pump Control Box and services based on the principle of excellence, honesty and customer first. On the basis of common development and win-win, we provide customers with all-round services and better solutions. Our company has a professional division of labor, a high degree of cooperation team, rich in strong product development strength and strong technical force.

Hot Tags: single pump water pump controller, single phase submersible control panel for flats', China, manufacturers, suppliers, factory, price, made in China, pump control for industrial environment, pump control for industrial unstacking, Intelligent Three Phase Pump Control Panel Easy Maintansess, pump controller for high reliability, Automatic Water Pump Controller With Segment LCD Screen Display, L532 Farms Three Phase Duplex Pump Control Panel 6PCS

Send Inquiry

whatsapp

Phone

E-mail