Highly-quality making certain subsistence, Administration marketing benefit, Credit score attracting customers for Intelligent Single Phase Water Pump Control Panel CE Cerfectation, Doi Starter 3 Phase Irrigation Pump Control Panel For Holidays House, L921 Automatic Water Pump Controller Panel With One Button Calibration, Pump Stalled Protection. Top quality, timely company and Aggressive cost, all win us a superior fame in xxx field despite the international intense competition. We have been recognized by the industry and praised by customers with a pious, dedicated attitude and continuous and stable quality. We build a responsible after-sales system, with sufficient stock, a wide variety of products, and high cost-effectiveness.
Single Pump Water Pump Controller, Single Phase Submersible Control Panel For Flats
| Product Details: Place of Origin:CHINA Brand Name:LEADING Certification:CE Model Number:L921 Payment & Shipping Terms: MinimumOrderQuantity:1 set Price:Negotiable PackagingDetails:Carton Delivery Time:30-35 days Payment Terms:D/A, D/P, T/T |
Detailed Product Description
Phase: | Single Phase | Pump Controlled Quantity: | One Pump |
Enclosure Protection Grade: | IP54 | Displaying: | LCD Display |
Liquid Level Transfer Distance: | ≤1000m | Unit Dimensions ( L X W X H): | 30.2 X 24x 12cm |
Products Brief :
L921 is applied for automatic liquid
level control / pressure control and effective protection for duplex pumps of with AC220V, 50hz, single phase output power 0.37 to 4kw (0.5hp-5.5hp),direct start, including stainless steel or cast iron submersible pump,centrifugal pump, sewage pump etc.Model L921 has many operation modes by adopting different electric installations. An important feature that makes the difference between Model L921 and common On/Off pump control box is the probe / sensor free in the well. Our special design makes it a very reliable and sensitive Protection against pump dry run without installation probe / sensor in the well.
Model L921 is useful in all cases we need to control and protect single pump managing its turn-on and turn off by different electric installations.
Typical Usage Scenarios Include:
Houses
Flats
Holidays houses
Farms
Water supply from wells
Irrigations of greenhouses, gardens, agriculture
Rain water reuse
Industrial plants
Waste water tank / Sewage sink
Main Technical Specifications
■ Rated Input Voltage…………………………………………………AC220V / Single Phase
■ Rated Frequency………………………………………………….……50Hz-60Hz (at option)
■ Rated Output Power of Motor………………………………0.37-2.2KW / 3-4KW(at option)
■ Short Circuit Trip Response Time………………………………………………………0.1sec
■ Dry Running Trip Response Time………………………………………………..……6sec
■ Over / Under Voltage Trip Response Time……………………………………….…5sec
■ Pump Stalled Trip Response Time……………………..………………………….0.5sec
■ Over Current Trip Response Time………………………………………………5sec-5min
■ Recovery Time of Over / Under Voltage………………………………………..……2min
■ Recovery Time of Over Current…………………………………………………..…30min
■ Recovery Time of Dry Running.…………………………………………………..……30min
■ Over / Under Voltage Trip……..……………………………….…………………..……±15%
■ Dry Running Trip……………………………………………….…………………..………70%
■ Pump Stalled Trip………………………………………….……………………..……200%
① the Characteristic of Inverse-time, the stronger of the current, The shorter of trip response time)
② Percent of rated input voltage ( i.e if the rated input voltage is 220V, the Over voltage trip is
253V, the Under voltage trip is 187V)
③ Percent of load time of calibration ( i.e if the running ampere of pump motor is 6A during the
calibration, the dry running trip ampere is 4.2A)
④ Percent of load time of calibration ( i.e if the running ampere of pump motor is 6A during the
calibration, The pump stalled trip ampere is 12A)
HTTP: www.leading-china.com
E-mail:stevenma89@hotmail.com
Model | L921 |
Start type | Direct on line |
Qty of controlled pump | Single pump |
Rated input voltage: | AC220V-240V Single phase 50HZ/ 60HZ |
Rated output power: | 0.37kw-2.2kw (0.5hp-3hp) |
Capacitor: | Reserved space for installing start capacitor |
Protection Offered: | Over load protection Pump stalled protection Dry run protection with sensor free Under voltage protection Over voltage protection |
Application & Control characteristic | Control and protect universal pump Using water level sensor or float switch to control pump start and stop Applied for water supply by liquid level control through float switch or liquid probe Applied for water supply by pressure control through pressure switch and pressure tank Applied for drainage by liquid level control through float switch or liquid probe |
Other features | Push button calibration Memory function when power off & recovery Interactive LCD Screen
|
Working temperature Working humidity Degree of protection Install position Unit dimension (L x W x H) | -25℃-- +55℃ 20%--90%RH, no drips concreted IP54 Wall mounting 30.2 x 24x 12cm |
Tag: single phase pump controller,single phase submersible pump control panel
Excellent product quality and competitive prices of our Water Pump Control for Water Engineering have given our company a good reputation among new and old customers. We believe that the most important thing is to achieve lean culture construction, so that everyone of the company can participate in it and give full play to the enthusiasm and creativity of each employee. By using our cutting-edge technology, we will continue to meet various challenges and achieve the company's long-term development.
Hot Tags: single pump water pump controller, single phase submersible control panel for flats', China, manufacturers, suppliers, factory, price, made in China, Black Intelligent Sewer Pump Control Panel Memory Stalled Protection, filtration control panel, Single Phase Pump Control Panel Reserved Space For Installing Start Capacitor, pump controller for uptime analysis, Duplex Single Phase Pump Control With Panel DOL Start, pump control for industrial standardization